    1. General Specifications

    Display: 3 1/2 digits, 1999 maximum Overloading:

    Under range displays UNDER Over range displays OVER Battery Deficiency:

    Drop Test: 1 meter pass Battery: 4 x 1.5V batteries (AA)

    Battery Life: Typical 20 hours continuous Dimension: 273 x 69 x 39mm Weight: around 386 g (including batteries)

    1. Environmental Requirements

    For indoor use only.

    Altitude: 2000m Temperature and humidity:

       Operating:

    0°C ~30°C (<80%R.H)

    30°C ~40°C (<75%R.H)

    40°C ~50°C (<45%R.H)

       Storage:

    -20°C ~ +60°C (<80%R.H)

    Safety/ Compliances:

    EN61326:1997 + A1:1998 + A2:2001 +A3:2003, EN61672-1: 2002 Class 2 and IEC60641:1979 Type 2, ANSI S1.4:1983 Type 2 Certification: C€

    Accuracy:±(a% reading + b digits).guarantee for 1 year. Operating temperature: 23°C±5°C .

    Relative humidity:<80%.

    Temperature coefficient: 0.1 x (specified accuracy) / 1°C

    DECIBEL DB

     

     

     

     

    Function

    Range

    Resolution

    Accuracy

    Remarks

    A-Weighting and C-Weighting

    30~80dB

    50~100dB

    60~110dB

    80~130dB

    0.1dB

    ±1.5dB

    Frequency

    Response

    31.5~8kHz

    Sampling Rate

    FAST

     

     

    Sampling Time: 125 microsecond

    SLOW

     

     

    Sampling Time: 1 second

    Analogue Bar Graph

    30~130dB

    1dB

     

    1 dB per scale, Sampling time: 200 times per second

     

    Overloading

     

     

     

    Over range display: OVER

    Under range display: UNDER

    DC analogue signal output

    Output

    impedance

    around

    1000, 10mV/dB

     

     

    Has input terminal

     

    Output

    impedance

    around

    6000, 0.707V/ each scale

     

     

    Has input terminal

    Power (HOLD)

     

     

     

    Turn on and off the Meter and data holding

    LEVEL (AUTO)

     

     

     

    Selecting auto and manual ranging

    A/C (RECALL/ CLR)

    A-Weighting and

    C-Weighting

    selection

     

     

    RECALL/CLR. Press to recall and clear data

    FAST/SLOW

    (STORE/BL)

    Selection of fast or slow sampling rate and turn on and off of display backlight

     

     